FLOW SENSOR REPLACEMENT
GLOW PLUG CIRCUIT BREAKER REPLACEMENT

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  335    336    337    338    339  340  341    342    343    344    345  
img
.
DRAFT
TM 5-4210-249-13&P-3
0390
INSTALLATION
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT02521A
NOTE
All flow sensors are installed the same way. Flow sensor on No. 1 discharge valve (driver
side) shown.
1.
Coat two preformed packings (6) with lubricating oil and install two preformed packings (6) on flow sensor (4).
NOTE
Alignment pin must align with hole in adapter before tightening nut.
2.
Align alignment pin (7) on flow sensor (4) with hole in adapter (5).
3.
Install flow sensor (4) on adapter (5) and tighten nut (3).
4.
Connect valve control wire harness connector (2) to flow sensor connector (1).
END OF TASK
FOLLOW-ON MAINTENANCE
Install pump house panel A (WP 0540)
END OF TASK
END OF WORK PACKAGE
0390-2