DRAFT
TM 5-4210-249-13&P-3
0392
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT04196
2.
Install wire 1413761 (9) on circuit breaker (10) with nut (8).
3.
Install wire 1413770 (7) on glow plug control relay (3) with nut (6).
4.
Install wire 1413766 (5) on glow plug control relay (3) with nut (4).
5.
Install pump house wire harness connector (2) on glow plug control relay (3) with retaining clip (1).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
6.
Apply sealing compound to electrical connections at wire 1413766 (5), wire 1413770 (7), and wire
1413761 (9).
END OF TASK
FOLLOW-ON MAINTENANCE
END OF TASK
END OF WORK PACKAGE
0392-3/(4 blank)