TM 5-4210-249-13&P-3
0370
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT04594
NOTE
Tag and mark wires and air lines prior to removal to ensure proper installation.
Remove cable ties as required.
Wires may be connected on terminal block in junction box, in positions other than shown.
Four wires from bumper turret and pump cooler dump-to-ground control valve solenoids
must first be identified and then removed from terminal block.
2.
Identify four wires (5), (6), (7), and (8) on bumper turret valve (9) and pump cooler dump-to-ground valve (10).
3.
Remove three screws (11) and four wires (5), (6), (7), and (8) from terminal block (12) and junction box (4).
4.
Cut three insulated eyes (13) from four wires (5), (6), (7), and (8) (TM 9-2320-325-14&P).
TFFT04595
5.
Remove two air lines (14) and (15) from fittings (16) and (17).
6.
Remove two air lines (18) and (19) from fittings (20) and (21).
0370-2