FOAM SYSTEM MANUAL METERING VALVE REPLACEMENT
FOAM SYSTEM MULTI-METERING VALVE (AUTOMATIC) REPLACEMENT

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  1290    1291    1292    1293    1294  1295  1296    1297    1298    1299    1300  
img
.
DRAFT
TM 5-4210-249-13&P-2
0291
INSTALLATION
TFFT00254
1.
Install two elbows (8) and (9) on foam system manual metering valve (4) (WP 0228).
2.
Install foam system manual metering valve (4) and two couplings (6) and (7) on vehicle (WP 0483).
NOTE
Install foam system manual metering valve as noted prior to removal.
3.
Install foam system manual metering valve (4) on bracket (5) with two cradles (3), U-bolts (2), and four
locknuts (1).
END OF TASK
FOLLOW-ON MAINTENANCE
Close pump operator's panel housing (WP 0325)
END OF TASK
END OF WORK PACKAGE