DRAFT
TM 5-4210-249-13&P-2
0292
INSTALLATION
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
CAUTION
Use sealing compound sparingly only on pipe threads. Do not apply compound to
hose connections. Damage to equipment may result.
1.
Apply sealing compound to threads of six elbows (2).
2.
Install six elbows (2) on multi-metering valve (5).
3.
Install multi-metering valve (5) on bracket (16) with two washers (20) lockwashers (19) and screws (18).
NOTE
Bracket and multi-metering valve are installed on pump house frame as an assembly.
4.
Install bracket (16) on frame (17) with two screws (15), four washers (14), two lockwashers (13), and
nuts (12).
5.
Connect two connectors (10) on electronic control unit (11).
6.
Install two couplings (8) and (9) and tee (6) on vehicle (WP 0483).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0292-3