DRAFT
TM 5-4210-249-13&P-2
FIELD LEVEL MAINTENANCE
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanic's: Automotive
Pump house panels G, H, and I
(WP 0622, Item 27)
removed (WP 0540)
Pump operator's panel housing
Materials/Parts
opened (WP 0325)
Lockwire (WP 0625, Item 31)
Locknut (6)
Water pump engine noise panel
References
WP 0615, Fig. 11
REMOVAL
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00776
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 13
Exhaust pipe and muffler can become very hot during vehicle operation. Be careful
not to touch these parts with bare hands, or allow body to come in contact with pipe
or muffler. Exhaust system parts can become hot enough to cause serious burns.
Failure to comply may result in damage to equipment or injury to personnel.
NOTE
Note routing of exhaust pipes and position of connections prior to removal to ensure
proper installation.
Remove exhaust pipe as one piece and disassemble sections after removal.
1.
Remove elbow (1) from reducer (2).
0228-1