DRAFT
TM 5-4210-249-13&P-2
0289
INSTALLATION
TFFT00081
1.
Install two couplings (6) and (7) and foam system flush valve (5) on vehicle (WP 0483).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
CAUTION
Use sealing compound sparingly only on pipe threads. Do not apply compound to
hose connections. Damage to equipment may result.
2.
Apply sealing compound to threads of two elbows (3) and (4).
3.
Install two air lines (1) and (2) and elbows (3) and (4) on foam system flush valve (5).
END OF TASK
FOLLOW-ON MAINTENANCE
Close pump house panel A (WP 0539)
END OF TASK
END OF WORK PACKAGE
0289-2