DRAFT
TM 5-4210-249-13&P-2
0267
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
20. Apply electrical sealant on end of wire (2).
END OF TASK
FOLLOW-ON MAINTENANCE
Close pump house panel A (WP 0539)
END OF TASK
END OF WORK PACKAGE
0267-7/(8 blank)