DRAFT
TM 5-4210-249-13&P-2
0268
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT01992C
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 72
Care must be taken when removing cable wire from arm and bracket. Wire is under
tension and must be held until safely repositioned. Failure to comply may result in
injury to personnel.
2.
Straighten cable wire (4).
3.
Loosen screw (5) and remove retainer (6) from cable wire (4).
NOTE
Note position of cable prior to removal to ensure proper installation.
4.
Remove two nuts (7), lockwashers (8), four washers (9), two screws (10), cushion clips (11), and cable (12)
5.
Remove cable wire (4) from pin (14).
NOTE
Number of washers may vary.
Note position of washers prior to replacement to ensure proper installation.
6.
Remove pin (14) and washer (15) from arm (16).
7.
Remove line (17) from elbow (18).
8.
Remove line (19) from elbow (20).
0268-2