DRAFT
TM 5-4210-249-13&P-2
0260
INSTALLATION
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT04101
1.
Install primer pump control solenoid (4) on primer pump motor (3) with two screws (11).
2.
Install power wire (10) on primer pump control solenoid (4) with locknut (9).
3.
Install jumperwire (8) on primer pump control solenoid (4) with locknut (7).
4.
Install wire 2774 (6) on primer pump control solenoid (4) with locknut (5).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
5.
Apply sealing compound to connections of power wire (10), jumperwire (8), and wire 2774 (6).
6.
Install electrical strip (2) on primer pump motor (3) and primer pump control solenoid (4) with two locknuts (1).
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Connect batteries (TM 9-2320-325-14&P)
2.
Remove wheel chocks (TM 9-2320-347-10)
END OF TASK
END OF WORK PACKAGE
0260-2