HIGH PRESSURE WATER SOURCE INTAKE RELIEF VALVE SETTING
MAIN INTAKE RELIEF/DUMP VALVE (DRIVER SIDE) REPLACEMENT

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  1171    1172    1173    1174    1175  1176  1177    1178    1179    1180    1181  
img
DRAFT
TM 5-4210-249-13&P-2
0257
TFFT00320
NOTE
One full turn of stem is equal to approximately 25 psi (172 kPa).
To reduce intake relief valve setting, loosen stem. To increase intake relief valve setting,
tighten stem.
1.
Loosen or tighten stem (2) to desired intake relief valve setting.
2.
Carefully tighten jamnut (1) on stem (2).
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-347-10)
END OF TASK
END OF WORK PACKAGE