DRAFT
TM 5-4210-249-13&P-2
0255
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT01569
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - .
WARNING
ICON 10 AND 12
Keep out from under heavy parts. Falling parts may cause serious injury or death.
NOTE
Installing water pump guide pins aids in attaching pump engine. Water pump guide pins
should be installed on engine in holes as shown.
6.
Install three water pump guide pins on engine (164).
CAUTION
Be sure pump and suitable lifting device are clear of all hoses and harnesses to
prevent damage to equipment.
Two drain hoses attached to pump must be installed with pump in same position as
noted prior to removal.
Cable ties are temporarily used to secure hoses, pipe (154), hose (153), and wires to
allow an open travel path for pump installation. Failure to comply may result in
damage to equipment.
7.
Install cable ties on wires and hoses.
0255-20