19. Apply electrical sealant on end of wire (163).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00590
20. Apply thread lock adhesive to three screws (168).
21. Install three remaining screws (168) and cushion clip (169) on pump (82) and engine (164). Tighten screws to
23 lb-ft (31 Nm).
22. Apply sealant to three screws (168) to mark torque point.
23. Remove cable ties that were temporarily used to secure hoses and wires.