WATER PUMP REPLACEMENT - Continued
WATER PUMP REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  1145    1146    1147    1148    1149  1150  1151    1152    1153    1154    1155  
img
DRAFT
TM 5-4210-249-13&P-2
0255
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00590
CAUTION
Two screws holding chain must be installed in the corner holes closest to the
pump's top discharge. Failure to comply will make pump removal more difficult and
may cause damage to equipment.
Chain must be installed on pump as tight as possible, still allowing for suitable
lifting device to be attached.
58. Attach chain (165) to pump (82) with eight washers (166) and two screws (167).
NOTE
Lifting strap attached to front of pump and around suitable lifting device helps to keep
pump level during removal.
59. Attach suitable lifting device to chain (165) and lifting strap.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -