TM 5-4210-249-13&P-2
0217
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT0349A
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 26 44
Wear protective goggles and nonleather gloves when servicing air conditioner or
injury may result.
3.
Close recovery/recycling station hand valves (5) and (6).
NOTE
Push down firmly on hose connectors until a clicking sound is heard to make sure coupler
is locked.
4.
Connect hose (7) to hand valve (8).
5.
Connect hose (7) and valve (8) to service valve (2).
6.
Connect hose (9) to hand valve (10).
7.
Connect hose (9) and hand valve (10) to service valve (4).
8.
Connect center hose (11) to recovery/recycling station (12) and receiving container (13).
9.
Open valve (14) on receiving container (13).
10. Turn coupler valve (8) to open position.
11. Turn coupler valve (10) to open position.
12. Recover all refrigerant from system to 10 to 15 in. Hg vacuum on low-side gauge of recovery/recycling station.
0217-5