DRAFT
TM 5-4210-249-13&P-2
0217
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00349A
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 26 44
Wear protective goggles and nonleather gloves when servicing air conditioner or
injury may result.
3.
Close two recover/recycling station hand valves (5) and (6).
NOTE
Push down firmly on hose connectors until a clicking sound is heard to make sure coupler
is locked.
4.
Connect hose (7) to hand valve (8).
5.
Connect hose (7) and hand valve (8) to service valve (2).
6.
Connect hose (9) to hand valve (10).
7.
Connect hose (9) and hand valve (10) to service valve (4).
8.
Connect center hose (11) to recovery/recycling station (12) and receiving container (13).
9.
Open valve (14) on receiving container (13).
10. Turn valve (8) clockwise to open position (8).
11. Turn valve (10) clockwise to open position (10).
0217-2