DRAFT
TM 5-4210-249-13&P-2
0217
EVACUATION/RECYCLING
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00349
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 26 44
Wear protective goggles and nonleather gloves when servicing air conditioner or
injury may result.
CAUTION
Always comply with all local regulations regarding refrigerant disposal. Failure to
comply may result in penalties for improper disposal.
System must have been recovered and compressor filled with correct amount of
refrigerant oil.
Air conditioner receiver/dryer must be replaced each time air conditioning system
refrigerant is evacuated or damage to system may result.
NOTE
Service valves are located under crew cab seat.
1.
Remove cap (1) from service valve (2).
2.
Remove cap (3) from service valve (4).
0217-4