PUMP ENGINE RUNNING INDICATOR NOT ILLUMINATED WHEN WATER PUMP ENGINE IS RUNNING - Continued
PUMP HOT ALARM/INDICATOR DOES NOT OPERATE WHEN TESTED OR PUMP OVERHEAT CONDITION (PUMP OPERATOR'S PANEL)

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  170    171    172    173    174  175  176    177    178    179    180  
img
DRAFT
TM 5-4210-249-13&P-2
0137
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04637
Step 14.
Stop water pump engine (WP 0022). Turn battery disconnect switch to OFF
position (WP 0007). Disconnect main wire harness pump house wire harness
connector. With a test lead set, check for continuity across wire 2670 (yellow) from
main wire harness pump house connector terminal 3, to water pump engine oil pressure
switch.
a.
If continuity is present, repair wire 2670 in main wire harness if
repairable (TM 9-2320-325-14&P), or replace main wire
harness (WP 0455).
b.
If continuity is not present, repair wire 2670 in pump house wire
harness if repairable (TM 9-2320-325-14&P), or replace pump house
wire harness (WP 0458).
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Install cab instrument panel B if removed (WP 0311)
2.
Install skid plate grille if removed (WP 0550)
3.
Remove wheel chocks (TM 9-2320-347-10)
END OF TASK
END OF WORK PACKAGE
0137-9/(10 blank)