WINDSHIELD DELUGE SYSTEM DOES NOT OPERATE PROPERLY - Continued
WINDSHIELD DELUGE SYSTEM DOES NOT OPERATE PROPERLY - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  1027    1028    1029    1030    1031  1032  1033    1034    1035    1036    1037  
img
DRAFT
TM 5-4210-249-13&P-1
0125
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT02723
Step 12.
Install circuit breaker 12 (WP 0398). Remove pump house panel S (WP 0540). Open
pump house power distribution box (WP 0412). Remove circuit breaker P2 (WP 0412).
Check for continuity across circuit breaker.
If there is no continuity, replace circuit breaker P2 (WP 0412).
0125-11