DRAFT
TM 5-4210-249-13&P-1
0125
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT02772
Step 6.
Put WINDSHIELD DELUGE switch to off position (WP 0004). Connect hose to
windshield deluge pump outlet hose coupler. Remove strainer screen from windshield
deluge automatic drain valve (WP 0562). Check if automatic drain valve strainer screen
is clogged.
a.
If strainer is free from clogs, replace hose from windshield deluge pump
to windshield deluge automatic drain valve (WP 0490).
b.
If strainer is not free from clogs, clean screen or replace windshield
deluge automatic drain valve (WP 0562).
0125-6