WINDSHIELD DELUGE SYSTEM DOES NOT OPERATE PROPERLY - Continued
WINDSHIELD DELUGE SYSTEM DOES NOT OPERATE PROPERLY - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  1025    1026    1027    1028    1029  1030  1031    1032    1033    1034    1035  
img
DRAFT
TM 5-4210-249-13&P-1
0125
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
NOTE
Water tank must be drained before removing windshield deluge shutoff valve strainer
screen. Water will be discharged from water tank uncontrolled, when windshield deluge
valve strainer is removed.
Step 10.
Remove windshield deluge shutoff valve strainer screen (WP 0561). Check if strainer
screen is clogged.
a.
If strainer screen is clogged, clean or replace strainer screen
(WP 0561).
b.
If strainer screen is not clogged, replace windshield deluge shutoff
valve (WP 0582).