WATER TANK DRAIN VALVE DOES NOT OPERATE WHEN SELECTED - Continued
WATER TANK DRAIN VALVE DOES NOT OPERATE WHEN SELECTED - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  994    995    996    997    998  999  1000    1001    1002    1003    1004  
img
. .
DRAFT
TM 5-4210-249-13&P-1
0122
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03623
Step 8.
Put pump operator's panel WATER TANK DRAIN switch to CLOSED
position (WP 0004). Turn battery disconnect switch to OFF position (WP 0007).
Disconnect main wire harness pump operator's panel wire harness connector D02.
With a test lead set, check for continuity across main wire harness wire 4053 (brown)
from main wire harness pump operator's panel wire harness connector D02, terminal 4
to main wire harness valve control wire harness connector DV1, terminal 6.
a.
If there is continuity, repair wire 4053 in pump operator's panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump
operator's panel wire harness (WP 0459).
b.
If there is no continuity, repair wire 4053 in main wire harness if
repairable (TM 9-2320-325-14&P), or replace main wire
harness (WP 0455).
0122-9