WATER TANK DRAIN VALVE DOES NOT OPERATE WHEN SELECTED - Continued
WATER TANK DRAIN VALVE DOES NOT OPERATE WHEN SELECTED - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  990    991    992    993    994  995  996    997    998    999    1000  
img
. . .
DRAFT
TM 5-4210-249-13&P-1
0122
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 3.
If system air pressure is below 85 psi (586 kPa), start vehicle engine and allow system
air pressure to build to at least 85 psi (586 kPa) (TM 9-2320-347-10). Shut off vehicle
engine (TM 9-2320-347-10). Disconnect air lines at water tank drain valve. While an
assistant puts pump operator's panel WATER TANK DRAIN switch to OPEN and
CLOSED positions (WP 0004), check if air pressure is present at water tank drain valve
blue and red air lines.
If there is air pressure, replace water tank drain valve (WP 0279).
TFFT03620
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle. Jewelry can catch on equipment and cause serious injury. Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 4.
Put WATER TANK DRAIN switch to CLOSED position (WP 0004). Connect air lines at
water tank drain valve. Disconnect valve control wire harness water tank drain control
valve connector. Put pump operator's panel WATER TANK DRAIN switch to OPEN
position (WP 0004). With a test lead set, check for 22 to 28 VDC between valve control
wire harness wire 4053 (brown) at water tank drain control valve connector, terminal 1
and a known good ground.
If 22 to 28 VDC are not present, go to Step 6.
0122-5