DRAFT
TM 5-4210-249-13&P-1
0105
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT02800
Step 32.
Open pump operator's panel housing (WP 0325). Check for 22 to 28 VDC between
pump operator's panel wire harness wire 2314 (red) at DIRECT TANK FILL switch
terminal and a known good ground.
If 22 to 28 VDC are not present, go to Step 34.
Step 33.
Turn battery disconnect switch to OFF position (WP 0007). Check for continuity across
pump operator's panel DIRECT TANK FILL switch from terminal wire 2314 (red) to
terminal wire 2315 (yellow), when switch is in OPEN position.
If there is no continuity, replace DIRECT TANK FILL switch (WP 0337).
0105-27