FOAM SYSTEM CANNOT BE FLUSHED - Continued
FOAM SYSTEM CANNOT BE FLUSHED - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  587    588    589    590    591  592  593    594    595    596    597  
img
. .
DRAFT
TM 5-4210-249-13&P-1
0101
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03962
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle. Jewelry can catch on equipment and cause serious injury. Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 16.
Put personnel cab PUMP COOLER switch to off position (WP 0004). Turn battery
disconnect switch to OFF position (WP 0007). Remove personnel cab instrument panel
A (WP 0311). Remove circuit breaker 10 from cab power distribution block (WP 0398).
Check for continuity across circuit breaker.
a.
If there is continuity, replace cab power distribution wire harness and
block (WP 0441).
b.
If there is no continuity, replace circuit breaker 10 (WP 0398).