FOAM SYSTEM CANNOT BE FLUSHED - Continued
FOAM SYSTEM CANNOT BE FLUSHED - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  583    584    585    586    587  588  589    590    591    592    593  
img
.
DRAFT
TM 5-4210-249-13&P-1
0101
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03958
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle. Jewelry can catch on equipment and cause serious injury. Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 12.
Turn battery disconnect switch to ON position (WP 0007). Check for 22 to 28 VDC
between wire 2834 (red) at FOAM FLUSH switch, terminal to a known good ground.
a.
If 22 to 28 VDC are not present, repair wire 2834 in pump operator's
panel wire harness if repairable (TM 9-2320-325-14&P), or replace
pump operator's panel wire harness (WP 0459).
b.
If 22 to 28 VDC are present, replace FOAM FLUSH switch (WP 0338).
0101-11


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.