FOAM SYSTEM CANNOT BE FLUSHED - Continued
FOAM SYSTEM CANNOT BE FLUSHED - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  584    585    586    587    588  589  590    591    592    593    594  
img
.
DRAFT
TM 5-4210-249-13&P-1
0101
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03959
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle. Jewelry can catch on equipment and cause serious injury. Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 13.
Turn battery disconnect switch to OFF position (WP 0007). With a test lead set, check
for continuity across wire 2200 (black) from valve control wire harness foam flush
shutoff control valve connector, terminal 2 to a known good ground.
If there is continuity, replace shutoff control valve manifold (WP 0427).