FOAM NOT DELIVERED WHEN TANK A IS SELECTED (BUMPER TURRET, GROUND SWEEPS, AND MANUAL METERING CONTROLS) - Continued
FOAM NOT DELIVERED WHEN TANK A IS SELECTED (BUMPER TURRET, GROUND SWEEPS, AND MANUAL METERING CONTROLS) - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  504    505    506    507    508  509  510    511    512    513    514  
img
. . . . .
DRAFT
TM 5-4210-249-13&P-1
0095
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04048
Step 24.
Put pump operator's panel FOAM TANK switch to "B" position (WP 0004). Check if
foam B indicator illuminates (WP 0004).
If foam B indicator illuminates, go to Step 26.
TFFT04049
Step 25.
Turn battery disconnect switch to OFF position (WP 0007). Open pump operator's
panel housing (WP 0325). Turn battery disconnect switch to ON position (WP 0007).
Put pump operator's panel FOAM SYSTEM switch to ON position (WP 0004). Check
for 22 to 28 VDC between wire 2830 (red) at FOAM TANK switch, terminal to a known
good ground.
a.
If 22 to 28 VDC are present, replace pump operator's panel FOAM
TANK switch (WP 0337).
b.
If 22 to 28 VDC are not present, repair wire 2830 in pump operator's
panel wire harness if repairable (TM 9-2320-325-14&P), or replace
pump operator's panel wire harness (WP 0459).
0095-16