FOAM NOT DELIVERED WHEN TANK A IS SELECTED (BUMPER TURRET, GROUND SWEEPS, AND MANUAL METERING CONTROLS) - Continued
FOAM NOT DELIVERED WHEN TANK A IS SELECTED (BUMPER TURRET, GROUND SWEEPS, AND MANUAL METERING CONTROLS) - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  499    500    501    502    503  504  505    506    507    508    509  
img
. .
DRAFT
TM 5-4210-249-13&P-1
0095
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04100
Step 17.
Turn battery disconnect switch to OFF position (WP 0007). Drain foam A
tank (WP 0031). Remove foam system A check valve (WP 0282). Check foam A
check valve for blockage and/or damage.
a.
If foam A check valve has blockage, remove blockage and reinstall
foam A check valve (WP 0282). If foam check valve is damaged,
replace foam A check valve (WP 0282).
b.
If foam A check valve is not blocked or damaged, replace foam system
A shutoff valve (WP 0284).
0095-11