FOAM NOT DELIVERED WHEN TANK A IS SELECTED (BUMPER TURRET, GROUND SWEEPS, AND MANUAL METERING CONTROLS) - Continued
FOAM NOT DELIVERED WHEN TANK A IS SELECTED (BUMPER TURRET, GROUND SWEEPS, AND MANUAL METERING CONTROLS) - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  503    504    505    506    507  508  509    510    511    512    513  
img
.
DRAFT
TM 5-4210-249-13&P-1
0095
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04047
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle. Jewelry can catch on equipment and cause serious injury. Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 23.
Turn battery disconnect switch to OFF position (WP 0007). Remove driver side crew
cab access panel (WP 0499). Remove pump house panel Q (WP 0540). Disconnect
main wire harness valve control wire harness connector DV1. With a test lead set,
check for continuity across valve control wire harness wire 2842 (red) from main wire
harness valve control wire harness connector DV1, terminal 3 to valve control wire
harness foam A shutoff control valve connector, terminal 1.
a.
If there is continuity, repair wire 2842 in main wire harness if
repairable (TM 9-2320-325-14&P), or replace main wire
harness (WP 0455).
b.
If there is no continuity, repair wire 2842 in valve control wire harness if
repairable (TM 9-2320-325-14&P), or replace valve control wire
harness (WP 0463).
0095-15