WATER PUMP ENGINE PRESSURE GOVERNOR CONTROLS DO NOT MAINTAIN SYSTEM PRESSURE WHEN DISCHARGE VALVE IS BEING OPENED OR CLOSED
WATER PUMP ENGINE PRESSURE GOVERNOR CONTROL PANEL PSI PRESET CONTROL DOES NOT OPERATE - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  410    411    412    413    414  415  416    417    418    419    420  
img
. . . . . . . . . . .
DRAFT
TM 5-4210-249-13&P-1
0083
FIELD LEVEL MAINTENANCE
WATER PUMP ENGINE PRESSURE GOVERNOR CONTROL PANEL PSI
PRESET CONTROL DOES NOT OPERATE
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanic's: Automotive
Water pump engine OFF (WP 0022)
(WP 0622, Item 27)
Engine OFF (TM 9-2320-347-10)
Wheels chocked (TM 9-2320-347-10)
References
WP 0004
WP 0022
WP 0024
WP 0078
WP 0193
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
WATER PUMP ENGINE PRESSURE GOVERNOR CONTROL PANEL PSI PRESET CONTROL DOES NOT
OPERATE
NOTE
Preset value for the pump operator's panel pressure governor control is set by
manufacturer to 125 psi (862 kPa).
Step 1.
Start water pump engine (WP 0022). Operate pump operator's panel pressure
governor in PSI mode (WP 0024). Press PRESET switch (WP 0004). Check if water
pump pressure increases to preset value.
If water pump pressure does not increase to preset value, go to Step 4.
NOTE
Preset value for the pump operator's panel pressure governor control is set by
manufacturer to 225 psi (1,551 kPa).
Step 2.
Operate personnel cab pressure governor in PSI mode (WP 0024). Press PRESET
switch (WP 0004). Check if water pump pressure increases to preset value.
If water pump pressure increases to preset parameter, fault corrected.
0083-1