• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
WATER PUMP ENGINE PRESSURE GOVERNOR CONTROL PANEL CHANGES ENGINE SPEED, BUT OSCILLATES WHILE IN RPM MODE
WATER PUMP ENGINE PRESSURE GOVERNOR CONTROL PANEL CHANGES ENGINE SPEED, BUT OSCILLATES WHILE IN RPM MODE - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  399    400    401    402    403  404  405    406    407    408    409  
img
. .
DRAFT
TM 5-4210-249-13&P-1
0080
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04435
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle. Jewelry can catch on equipment and cause serious injury. Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 2.
Turn water pump engine off (WP 0022). Turn battery disconnect switch to OFF
position (WP 0007). Open pump house panel A (WP 0539). Disconnect pump
operator's panel wire harness ECU wire harness connector. Open pump operator's
panel housing (WP 0325). Disconnect pump operator's panel wire harness pump
operator's panel pressure governor 12-terminal wire harness connector. With a test
lead set, check for continuity across wire 1967 from pump operator's panel pressure
governor 12-terminal connector, terminal 9 to ECU connector, terminal 23.
If continuity is not present, repair wire 1967 in pump operator's panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump operator's
panel wire harness (WP 0459).
0080-2


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.