DRAFT
TM 5-4210-249-13&P-1
0080
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04440
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle. Jewelry can catch on equipment and cause serious injury. Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 9.
Remove driver side crew cab access panel (WP 0499). Remove pump house panel
Q (WP 0540). Disconnect main wire harness pump operator's panel wire harness
connector DO 2. With a test lead set, check for continuity across wire 1966 from main
wire harness personnel cab pressure governor 12-terminal connector, terminal 1 to
main wire harness pump operator's panel wire harness connector DO 2, terminal 6.
a.
If continuity is present, repair wire 1966 in pump operator's panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump
operator's panel wire harness (WP 0459).
b.
If continuity is not present, repair wire 1966 in main wire harness if
repairable (TM 9-2320-325-14&P), or replace main wire
harness (WP 0455).
0080-7