TM 5-4210-249-13&P-1
OPERATOR LEVEL MAINTENANCE
EXTENDABLE FLOODLIGHTS DO NOT OPERATE
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
References
Equipment Conditions
Engine OFF (TM 9-2320-347-10)
Wheels chocked (TM 9-2320-347-10)
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
EXTENDABLE FLOODLIGHTS DO NOT OPERATE
Step 1.
Turn battery disconnect switch to ON position (WP 0007). Start
engine (TM 9-2320-347-10). Start hydraulic generator (WP 0021). Check if 120 VAC
outlets operate.
If all 120 VAC outlets do not operate, troubleshoot 120 VAC Outlet(s) Does
TFFT04060
NOTE
Circuit breaker may be in ON position when tripped. To make sure circuit breaker is not
tripped, reset circuit breaker by switching it to OFF position then back to ON position.
Step 2.
Check if circuit breaker 5 or 6 is tripped.
a.
If circuit breaker 5 or 6 is tripped, reset tripped circuit breaker.
b.
If circuit breaker trips again, notify Supervisor.