OPERATION IN COLD ENVIRONMENT, -25 TO 32F (-32 TO 0C) - Continued
OPERATION IN COLD ENVIRONMENT, -25 TO 32F (-32 TO 0C) - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  197    198    199    200    201  202  203    204    205    206    207  
img
. . . . .
DRAFT
TM 5-4210-249-13&P-1
0045
PREPARATION FOR COLD WEATHER OPERATION
1.
Make sure truck has been parked in a warm shelter (55F [13C]) or higher prior to operations.
TFFT00645P
2.
Install pump house cooling winterization cover (1) on left side pump house panel (2) with eight twist locks (3).
3.
Make sure onboard water tank is full (WP 0020).
4.
Make sure foam agent tanks are filled (WP 0031). Use Class A foam agent or a Class B foam agent rated for
a minimum of -20F (-29C).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00644P
5.
Start hydraulic generator (WP 0021).
6.
Put water tank heater circuit breakers (CB11, CB13) (4) and pipe heaters circuit breaker (CB15) (5) on
breaker box (6) to ON position.
7.
Make sure water pump is drained and in a "dry condition" (WP 0032).
8.
Make sure water pump and plumbing have been blown out (WP 0044).
9.
Make sure all valves are closed and caps are installed.
END OF TASK