PUMP AND PLUMBING BLOW-OUT PROCEDURES - Continued
PUMP AND PLUMBING BLOW-OUT PROCEDURES - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  192    193    194    195    196  197  198    199    200    201    202  
img
DRAFT
TM 5-4210-249-13&P-1
0044
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00291P
41. Let pressure build up to 50 psi (345 kPa) on PUMP DISCHARGE gauge (13). Open MASTER DRAIN
valve (4).
42. When water stops draining from MASTER DRAIN valve (4), close MASTER DRAIN valve (4).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00706AP
43. Disconnect air hose (10) from regulated air supply and blow-out adapter (7) on PASSENGER SIDE
AUXILIARY INLET (6).
44. Stow air hose (10).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00996P
45. Remove and stow blow-out adapter (7) from PASSENGER SIDE AUXILIARY INLET (6).
46. Install cap (5) on PASSENGER SIDE AUXILIARY INLET (6).
0044-9