DRAFT
TM 5-4210-249-13&P-1
OPERATOR MAINTENANCE
WATER TANK FILL
NOTE
The TFFT can be filled four different ways.
MAIN INLET
TFFT02191
NOTE
Valve is completely closed when red indicator light illuminates.
Main Inlet may be operated with either 5 in. (13 cm) or 3 in. (7.6 cm) soft suction hose.
5 in. (13 cm) and 3 in. (7.6 cm) suction hoses operate the same way. 5 in. (13 cm) suction
hose shown.
1.
Push DRIVER MAIN INLET valve control CLOSE button (1) until red indicator light (2) illuminates.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0020-1