PUMPING FROM HYDRANT OR IN RELAY (POSITIVE WATER SOURCES)
PUMPING FROM HYDRANT OR IN RELAY (POSITIVE WATER SOURCES) - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  119    120    121    122    123  124  125    126    127    128    129  
img
DRAFT
TM 5-4210-249-13&P-1
0027
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00323P
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 66
Open and close all valves slowly during any procedure. Sudden changes in
pressure may cause equipment to react faster than personnel can be alerted.
Ensure surrounding personnel are aware of changes being made to settings on
equipment. Failure to comply may result in injury or death to personnel and
damage to equipment.
5.
Open supply valve on positive water source.
6.
Open DRIVER MAIN INLET bleeder valve (3) or PASSENGER SIDE AUX. INLET bleeder valve (4) until water
discharges to ground.
7.
Close DRIVER MAIN INLET bleeder valve (3) or PASSENGER SIDE AUX. INLET bleeder valve (4).