PUMPING FROM ONBOARD WATER TANK - Continued
PUMPING FROM HYDRANT OR IN RELAY (POSITIVE WATER SOURCES)

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  117    118    119    120    121  122  123    124    125    126    127  
img
. .
DRAFT
TM 5-4210-249-13&P-1
0026
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT04841
14. Put DIRECT TANK FILL switch (10) to AUTO position. Indicator lights (11) and (12) will illuminate.
15. Complete mission.
16. Shut off water pump engine (WP 0022).
NOTE
Perform Steps (17) through (21) if direct tank fill was performed.
17. Shut off positive water source valve.
18. Put DIRECT TANK FILL switch (10) to OPEN position. Indicator light (11) will go out.
19. Relieve pressure in hose, if necessary, put DIRECT TANK FILL switch (10) to OFF position. Indicator
light (12) will go out.
20. Remove hose from positive water source and direct tank fill inlets as required.
21. Perform post operation procedures (WP 0041).
END OF TASK
END OF WORK PACKAGE