• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
PUMPING FROM ONBOARD WATER TANK - Continued
PUMPING FROM HYDRANT OR IN RELAY (POSITIVE WATER SOURCES) - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  118    119    120    121    122  123  124    125    126    127    128  
img
.
DRAFT
TM 5-4210-249-13&P-1
0027
OPERATOR MAINTENANCE
PUMPING FROM HYDRANT OR IN RELAY (POSITIVE WATER SOURCES)
NOTE
Make sure valves, drains, and caps are closed.
Foam system will not operate when pump intake pressure is more than 5 psi (34 kPa).
Main Inlet may be operated with either 5 in. (13cm) or 3 in. (7.6 cm) suction hose.
5 in. (13 cm) and 3 in. (7.6 cm) suction hoses operate the same way. 5 in. (13 cm) suction
hose shown.
1.
Position vehicle for convenient hydrant hookup and discharge hose layout. Bring vehicle to complete stop.
2.
Park vehicle (TM 9-2320-347-10).
TFFT00321P/00322P
NOTE
Pumping may be performed from either main inlet or PASSENGER SIDE AUX. INLET.
3.
Remove cap from either main inlet (1) or PASSENGER SIDE AUX. INLET (2).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 72
Do not use hard suction hose for Step (4). Hard suction hose will not hold pressure.
Hose may fail and separate causing injury to personnel and/or damage to
equipment.
4.
Connect either 5 in. (13 cm) soft suction hose to main inlet (1) or 3 in. (8 cm) discharge hose to PASSENGER
SIDE AUX. INLET (2).
0027-1


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.