Figure 16. Pump Operator's Panel - Middle/Lower Left (Sheet 2 of 2)
Figure 18. Pump Operator's Panel - Lower Right

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  44    45    46    47    48  49  50    51    52    53    54  
img
.
DRAFT
TM 5-4210-249-13&P-1
0004
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00043P
Figure 17.
Pump Operator's Panel - Lower Left.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Key
Control or Indicator
Function
Fig. 17
1
FOAM SYSTEM Switch
Lift and push switch right to turn on FOAM SYSTEM. Push switch
left to turn off FOAM SYSTEM.
2
FOAM SYSTEM Indicator Light
Illuminates when foam system is operational.
3
FOAM TANK Selector Switch
Lift and push switch left for class A foam; push switch to right for
class B foam. Switch automatically goes to center position when
released.
4
CLASS A FOAM Indicator Light
Illuminates when class A foam is selected.
5
CLASS B FOAM Indicator Light
Illuminates when class B foam is selected.
6
FOAM FLUSH Switch
Lift and push switch to right to turn on FOAM FLUSH. Push switch
to left to turn off FOAM FLUSH.
7
FOAM FLUSH Indicator Light
Illuminates when foam flush in ON position.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -