DRAFT
TM 5-4210-249-13&P-1
0004
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00045P
Figure 18.
Pump Operator's Panel - Lower Right.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Key
Control or Indicator
Function
Fig. 18
1
PUMP PRIMER Switch
Press to open pump primer valve and operate electric primer
pump.
2
Pump MANUAL PRIMER Control
Used to bypass electric control circuit for pump primer valve. Pull
handle to activate (open) pump primer valve.
3
DRIVER MAIN INLET PRIMER
Press to open driver main inlet primer valve and operate electric
Switch
primer pump.
4
Driver main inlet MANUAL
Used to bypass electric control circuit for driver main inlet manual
PRIMER Control
valve. Pull handle to activate (open) driver main inlet primer valve.
5
START PUMP ENGINE STOP
Push switch up to start water pump engine; push switch down to
Switch
stop water pump engine.
6
PUMP ENGINE RUNNING
Illuminates when water pump engine is running.
Indicator Light
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -