CYLINDER HEAD REPAIR - Continued
CYLINDER HEAD REPAIR - Continued

Maintenance Manual for Firefighting Truck, 100 Ft Aerial Ladder, 1000 GPM Page Navigation
  86    87    88    89    90  91  92    93    94    95    96  
img
.
TM 5-4210-233-14&P-2
6-14. CYLINDER HEAD REPAIR - Continued
(15) Remove four injectors (1) from injector
holes (2).
WARNING
Compressed air used for cleaning purposes
will not exceed 30 psi (207 kPa). Use only
with effective chip guarding and personal
protective
equipment
(goggles/shield,
gloves, etc.).
(16)Dry cylinder head with compressed air.
WARNING
Dry cleaning solvent P-D-680 is potentially
dangerous. Avoid repeated and prolonged
breathing of vapors and skin contact with the
liquid. Do not use near open flame, arcing
equipment or other ignition sources. Always
wear eye protection and protective clothing.
The flash point of P-D-680 is 100 to 138 deg
F(38 to 59deg. C).
(17) Clean cylinder head with dry cleaning
solvent (Item 3, Appendix E).
(18) Dry cylinder head with compressed air.
d. Assembly.