• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
FIRE PUMP - Continued
FIRE PUMP - Continued

Maintenance Manual for Firefighting Truck, 100 Ft Aerial Ladder, 1000 GPM Page Navigation
  19    20    21    22    23  24  25    26    27    28    29  
TM 5-4210-233-14&P-2
6-6. FIRE PUMP - Continued
(72) Install nipple (5), tee (4), hose (2) and adapter union (3) in discharge side of pump.
(73) Install street elbows (6) at sump strainer (7) and inlet of oil pump (45).
(74) Install adapter union (3) in elbow (6) at sump strainer (7).
(75) Install hose (1).
(76) Install screw retainers (104) in slot end of each screw (103).
(77) Install coverplate (101) and new gasket (102) with screws (99) and washers (100).
(78) Install drive shaft end yokes, install washers (86 and 87) and lock nuts (84 and 85); tighten nuts
securely. Make sure one slot in nut lines up with holes in ends of drive shaft (34) and coupling (32).
Install cotter pins (82 and 83) and spread open split ends of pins.