FIRE PUMP - Continued
FIRE PUMP - Continued

Maintenance Manual for Firefighting Truck, 100 Ft Aerial Ladder, 1000 GPM Page Navigation
  23    24    25    26    27  28  29    30    31    32    33  
img
TM 5-4210-233-14&P-2
6-6. FIRE PUMP - Continued
(5) Remove snap ring (4A) and use a puller to remove bearing housing (6) from shaft (12). Remove
bearing housing cap (1) and gasket (2) by first removing screws (3) and lockwashers (4). Discard
gasket. Remove retaining ring (9).
(6) Remove and discard oil seal (7). Carefully remove flinger disk (7A) and grommet (7B) from shaft (12).
Remove half glands (7C) and slide packing (8 and 8A), stuffing box ends (9), and wear rings (10) from
each end of shaft (12).
NOTE
Mark wear rings (10) or keep them with the side of impeller (11) from which they
were removed to permit checking impeller hub clearance later on.
(7) Remove snap ring (13) on each side of impeller
hub (11).