TM 9-4931-363-14&P
NOTE
If B1, R18, or R19 require replacement because
Remove items (1) through (5) in disassembly sequence
of a defect in one or more of these
and assemble in reverse disassembly sequence.
components, all three components must be
replaced. Resistors R18 and R19 are furnished
with the resolver as RT-2 and RT-1,
respectively. These resistors are matched and
i d e n t i f i e d with the resolver and must be
installed concurrently with replacement of the
a. Remove items (1) through (6) in disassembly
resolver.
sequence and assemble in reverse disassembly sequence.
outside of box, using a 5/32-inch drill. Drill 1/16 to 1/8
inch deep and remove the head of the rivet with a chisel.
Remove items (1) through (37) in disassembly sequence.
P u n c h out the remaining portion of the rivet with a
Unsolder and mark leads where necessary. Assemble in
1 / 8 - i n c h punch. Install new hinges using new rivets
reverse disassembly sequence.
furnished with the hinges.
Remove items (1) through (31) in disassembly sequence.
Unsolder and mark leads where necessary. Assemble in
The multimeter is fragile. Do not drop it during
reverse disassembly sequence.
disassembly and assembly of the top panel.
Remove items (1) through (48) in disassembly sequence.
Unsolder and mark leads where necessary. Assemble in
reverse disassembly sequence.
a. Remove items (1) through (36) in disassembly
sequence. U n s o l d e r and mark leads where necessary.
Assemble in reverse disassembly sequence.
Assembly (fig. B-11).
b. Removal of resolver B1 (item 32) requires
Remove items (1) through (3) from item (4). To
readjustment of B1 in accordance with paragraph 4-24.
reassemble, install items (1) through (3) in item (4).
|