PIPING HEAT TRACE REPLACEMENT - Continued
PIPING HEAT TRACE REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 4 Page Navigation
  230    231    232    233    234  235  236    237    238    239    240  
img
DRAFT
TM 5-4210-249-13&P-4
0606
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00958
NOTE
Tag and mark wires prior to removal to ensure proper installation.
Firmly insert a flat blade screwdriver in square hole to open spring in terminal. When fully
inserted, screwdriver will lock in place and wire can be removed from terminal.
2.
Remove two heat trace cable bus wires (5) from terminal (6).
3.
Remove heat trace braid (7) from terminal (6).
4.
Remove core sealer (8) from two heat trace cable bus wires (5).
5.
Remove tube (9) from heat trace braid (7).