POWER TAKE OFF (PTO) PUMP REPLACEMENT - Continued
POWER TAKE OFF (PTO) PUMP REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 4 Page Navigation
  206    207    208    209    210  211  212    213    214    215    216  
img
.
DRAFT
TM 5-4210-249-13&P-4
0601
INSTALLATION
TFFT00740
1.
Install elbow (10), fitting (14), and fitting (12) on PTO pump (15).
2.
Install hydraulic generator compensator (20) (WP 0584).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 07
PTO pump is heavy. Do not attempt to lift PTO pump without the aid of an assistant.
Failure to comply may result in injury to personnel.
3.
With the aid of an assistant, install PTO pump (15) on PTO (19) with two washers (18), lockwashers (17), and
screws (16).
TFFT1949
4.
Install hose (13) from fitting (14).
5.
Install fitting (11) on fitting (12).