HYDRAULIC GENERATOR REPLACEMENT - Continued
HYDRAULIC GENERATOR REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 4 Page Navigation
  177    178    179    180    181  182  183    184    185    186    187  
img
DRAFT
TM 5-4210-249-13&P-4
0592
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00393A
7.
Install hydraulic generator (16) on two brackets (49) with three screws (48), lockwashers (47), six washers
(46), and three nuts (45).
8.
Install ground wire (53), washer (52), lockwasher (51), and screw (50) on hydraulic generator (16).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
9.
Apply electrical sealant to ground wire (53).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -