HYDRAULIC GENERATOR REPLACEMENT - Continued
HYDRAULIC GENERATOR REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 4 Page Navigation
  173    174    175    176    177  178  179    180    181    182    183  
img
DRAFT
TM 5-4210-249-13&P-4
0592
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00392A
NOTE
Tag and mark wires prior to removal to ensure proper installation.
Note position and remove cable ties and cushion clips as required.
10. Remove nut (28) and wire (29) from stud (30).
11. Remove nut (31) and wire (32) from stud (33) and pull wire (32) through current transformer (34).
12. Remove nut (35) and wire (36) from stud (37) and pull wire (36) through current transformer (38).
13. Remove screw (39), washer (40), and wire (41) from electrical box (27).
14. Loosen collar (42) and remove four wires (29), (32), (36), and (41) from electrical box (27).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00392B
15. Disconnect connector (43).
16. Disconnect connector (44).